{"title":"Chiller Chemicals","description":"","products":[{"product_id":"pre-measured-chiller-water-additive-kit-with-citranox-70-gallon-tank","title":"Pre-Measured Chiller Water Additive Kit with Citranox - 70 Gallon Tank","description":"\u003ch5\u003e\u003cspan style=\"color: #b63a22;\"\u003e***CANNOT SHIP OUTSIDE THE UNITED STATES\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMade for a 70 Gallon Tank, Pre-Measured bottle of Citranox included.\u003c\/p\u003e\n\u003cp\u003eThis Kit Includes:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e1 Bottle of General Corrosion Inhibitor\u003c\/li\u003e\n\u003cli\u003e1 Bottle of Copper Corrosion Inhibitor\u003c\/li\u003e\n\u003cli\u003e1 Bottle of Biocide\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e1 Bottle of Citranox (only enough for a 70-gallon tank)\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFull contents of each bottle are added to the Distilled water in the chiller tank.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eDirections\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch2\u003eWater Flushing Procedure\u003c\/h2\u003e\n\u003cp\u003eThe purpose of these procedures is to make sure that new water and chemicals are installed in the chiller every three months for optimal performance of the laser cooling system. In addition, every sixth month the cooling system is also flushed of all debris and unwanted chemicals.\u003c\/p\u003e\n\u003ch2\u003eEvery 3 months:\u003c\/h2\u003e\n\u003cp\u003eReplace water by using these steps:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eDrain all the water in the tank\u003c\/li\u003e\n\u003cli\u003eFill with new distilled water\u003c\/li\u003e\n\u003cli\u003eAdd the full contents of each of the three bottles\u003cspan\u003e \u003c\/span\u003eto the distilled water in the chiller tank: \u003cspan\u003eGeneral Corrosion\u003c\/span\u003e\u003cspan\u003e Inhibitor, Copper Corrosion Inhibitor, and Biocide.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eEvery 6 months:\u003c\/h2\u003e\n\u003cp\u003eReplace water by using these steps:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eDrain all the water in the tank\u003c\/li\u003e\n\u003cli\u003eFill tank with tap water\u003c\/li\u003e\n\u003cli\u003eAdd the pre-measured bottle of \u003cspan\u003eCitranox\u003c\/span\u003e, or 0.5 gal of Citranox per 50 gal of water (0.7 gal of Citranox per 70 gal of water).\u003c\/li\u003e\n\u003cli\u003eRun the chiller for 6 hours with high voltage on\u003c\/li\u003e\n\u003cli\u003e Flush out all the Ctiranox:\u003c\/li\u003e\n\u003col\u003e\n\u003cli\u003eDrain all the water in the tank\u003c\/li\u003e\n\u003cli\u003eFill the tank with tap water only\u003c\/li\u003e\n\u003cli\u003eRun the chiller for 10 minutes\u003c\/li\u003e\n\u003cli\u003eRepeat 4 time to be sure all the Citranox is out of the water.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cli\u003eWith the tank empty, fill the tank using the “Every 3rd month” instructions.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Mazak®","offers":[{"title":"Default Title","offer_id":42651496415310,"sku":"ChillerChemMG70-C","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/1270\/7918\/files\/withcitranox_a87de029-53a5-452f-9376-c1a612de88e9.jpg?v=1781003066"},{"product_id":"pre-measured-chiller-water-additive-kit-with-citranox-30-gallon-tank","title":"Pre-Measured Chiller Water Additive Kit with Citranox - 30 Gallon Tank","description":"\u003ch5\u003e\u003cspan style=\"color: #b63a22;\"\u003e***CANNOT SHIP OUTSIDE THE UNITED STATES\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFor 30 Gallon Tank, Pre-Measured bottle of Citranox included.\u003c\/p\u003e\n\u003cp\u003eThis Kit Includes:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e1 Bottle of General Corrosion Inhibitor\u003c\/li\u003e\n\u003cli\u003e1 Bottle of Copper Corrosion Inhibitor\u003c\/li\u003e\n\u003cli\u003e1 Bottle of Biocide\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e1 Bottle of Citranox (only enough for a 30 gallon tank)\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFull contents of each bottle is added to the Distilled water in the chiller tank.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eDirections\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch2\u003eWater Flushing Procedure\u003c\/h2\u003e\n\u003cp\u003eThe purpose of these procedures is to make sure that new water and chemicals are installed in the chiller every three months for optimal performance of the laser cooling system. In addition, every sixth month the cooling system is also flushed of all debris and unwanted chemicals.\u003c\/p\u003e\n\u003ch2\u003eEvery 3 months:\u003c\/h2\u003e\n\u003cp\u003eReplace water by using these steps:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eDrain all the water in the tank\u003c\/li\u003e\n\u003cli\u003eFill with new distilled water\u003c\/li\u003e\n\u003cli\u003eAdd the full contents of each of the three bottles\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eto the Distilled water in the chiller tank: \u003cspan data-mce-fragment=\"1\"\u003eGeneral Corrosion\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e Inhibitor, Copper Corrosion Inhibitor, and Biocide.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eEvery 6 months:\u003c\/h2\u003e\n\u003cp\u003eReplace water by using these steps:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eDrain all the water in the tank\u003c\/li\u003e\n\u003cli\u003eFill tank with tap water\u003c\/li\u003e\n\u003cli\u003eAdd the pre-measured bottle of \u003cspan data-mce-fragment=\"1\"\u003eCitranox\u003c\/span\u003e, or 0.5 gal of Citranox per 50 gal of water. \u003c\/li\u003e\n\u003cli\u003eRun the chiller for 6 hours with high voltage on\u003c\/li\u003e\n\u003cli\u003e Flush out all the Ctiranox:\u003c\/li\u003e\n\u003col\u003e\n\u003cli\u003eDrain all the water in the tank\u003c\/li\u003e\n\u003cli\u003eFill the tank with tap water only\u003c\/li\u003e\n\u003cli\u003eRun the chiller for 10 minutes\u003c\/li\u003e\n\u003cli\u003eRepeat 4 time to be sure all the Citranox is out of the water.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cli\u003eWith the tank empty, fill the tank using the “Every 3rd month” instructions.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Mazak®","offers":[{"title":"Default Title","offer_id":42651496448078,"sku":"ChillerChemMG30-C","price":160.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/1270\/7918\/files\/withcitranox.jpg?v=1781003065"},{"product_id":"pre-measured-chiller-water-additive-kit-50-gallon-tank","title":"Pre-Measured Chiller Water Additive Kit - 50 Gallon Tank","description":"\u003ch5\u003e\u003cspan style=\"color: #b63a22;\"\u003e***CANNOT SHIP OUTSIDE THE UNITED STATES\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFor 50 Gallon Tank, No citranox included.\u003c\/p\u003e\n\u003cp\u003eThis Kit Includes:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e1 Bottle of General Corrosion Inhibitor\u003c\/li\u003e\n\u003cli\u003e1 Bottle of Copper Corrosion Inhibitor\u003c\/li\u003e\n\u003cli\u003e1 Bottle of Biocide\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFull contents of each bottle is added to the Distilled water in the chiller tank.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eDirections\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch2\u003eWater Flushing Procedure\u003c\/h2\u003e\n\u003cp\u003eThe purpose of these procedures is to make sure that new water and chemicals are installed in the chiller every three months for optimal performance of the laser cooling system. In addition, every sixth month the cooling system is also flushed of all debris and unwanted chemicals.\u003c\/p\u003e\n\u003ch2\u003eEvery 3 months:\u003c\/h2\u003e\n\u003cp\u003eReplace water by using these steps:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eDrain all the water in the tank\u003c\/li\u003e\n\u003cli\u003eFill with new distilled water\u003c\/li\u003e\n\u003cli\u003eAdd the full contents of each of the three bottles \u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eto the Distilled water in the chiller tank: \u003cspan data-mce-fragment=\"1\"\u003eGeneral Corrosion\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e Inhibitor, Copper Corrosion Inhibitor, and Biocide.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eEvery 6 months:\u003c\/h2\u003e\n\u003cp\u003eReplace water by using these steps:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eDrain all the water in the tank\u003c\/li\u003e\n\u003cli\u003eFill tank with tap water\u003c\/li\u003e\n\u003cli\u003eAdd the pre-measured bottle of \u003cspan data-mce-fragment=\"1\"\u003eCitranox\u003c\/span\u003e, or 0.5 gal of Citranox per 50 gal of water.\u003c\/li\u003e\n\u003cli\u003eRun the chiller for 6 hours with high voltage on\u003c\/li\u003e\n\u003cli\u003e Flush out all the Ctiranox:\u003c\/li\u003e\n\u003col\u003e\n\u003cli\u003eDrain all the water in the tank\u003c\/li\u003e\n\u003cli\u003eFill the tank with tap water only\u003c\/li\u003e\n\u003cli\u003eRun the chiller for 10 minutes\u003c\/li\u003e\n\u003cli\u003eRepeat 4 time to be sure all the Citranox is out of the water.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cli\u003eWith the tank empty, fill the tank using the “Every 3rd month” instructions.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Mazak®","offers":[{"title":"Default Title","offer_id":42651496480846,"sku":"ChillerChemMG50","price":165.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/1270\/7918\/files\/chemkits_3734fa64-7cc0-47d7-8ead-7f34511e786f.jpg?v=1781003065"},{"product_id":"pre-measured-chiller-water-additive-kit-70-gallon-tank","title":"Pre-Measured Chiller Water Additive Kit - 70 Gallon Tank","description":"\u003ch5\u003e\u003cspan style=\"color: #b63a22;\"\u003e***CANNOT SHIP OUTSIDE THE UNITED STATES\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFor 70 Gallon Tank, No citranox included.\u003c\/p\u003e\n\u003cp\u003eThis Kit Includes:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e1 Bottle of General Corrosion Inhibitor\u003c\/li\u003e\n\u003cli\u003e1 Bottle of Copper Corrosion Inhibitor\u003c\/li\u003e\n\u003cli\u003e1 Bottle of Biocide\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFull contents of each bottle is added to the Distilled water in the chiller tank.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eDirections\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch2\u003eWater Flushing Procedure\u003c\/h2\u003e\n\u003cp\u003eThe purpose of these procedures is to make sure that new water and chemicals are installed in the chiller every three months for optimal performance of the laser cooling system. In addition, every sixth month the cooling system is also flushed of all debris and unwanted chemicals.\u003c\/p\u003e\n\u003ch2\u003eEvery 3 months:\u003c\/h2\u003e\n\u003cp\u003eReplace water by using these steps:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eDrain all the water in the tank\u003c\/li\u003e\n\u003cli\u003eFill with new distilled water\u003c\/li\u003e\n\u003cli\u003eAdd the full contents of each of the three bottles \u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eto the Distilled water in the chiller tank: \u003cspan data-mce-fragment=\"1\"\u003eGeneral Corrosion\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e Inhibitor, Copper Corrosion Inhibitor, and Biocide.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eEvery 6 months:\u003c\/h2\u003e\n\u003cp\u003eReplace water by using these steps:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eDrain all the water in the tank\u003c\/li\u003e\n\u003cli\u003eFill tank with tap water\u003c\/li\u003e\n\u003cli\u003eAdd the pre-measured bottle of \u003cspan data-mce-fragment=\"1\"\u003eCitranox\u003c\/span\u003e, or 0.5 gal of Citranox per 50 gal of water.\u003c\/li\u003e\n\u003cli\u003eRun the chiller for 6 hours with high voltage on\u003c\/li\u003e\n\u003cli\u003e Flush out all the Ctiranox:\u003c\/li\u003e\n\u003col\u003e\n\u003cli\u003eDrain all the water in the tank\u003c\/li\u003e\n\u003cli\u003eFill the tank with tap water only\u003c\/li\u003e\n\u003cli\u003eRun the chiller for 10 minutes\u003c\/li\u003e\n\u003cli\u003eRepeat 4 time to be sure all the Citranox is out of the water.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cli\u003eWith the tank empty, fill the tank using the “Every 3rd month” instructions.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Mazak®","offers":[{"title":"Default Title","offer_id":42651496513614,"sku":"ChillerChemMG70","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/1270\/7918\/files\/chemkits_6eefd080-2099-4123-a81b-72b3a656fdb8.jpg?v=1781003064"},{"product_id":"pre-measured-chiller-water-additive-kit-30-gallon-tank","title":"Pre-Measured Chiller Water Additive Kit - 30 Gallon Tank","description":"\u003ch5\u003e\u003cspan style=\"color: #b63a22;\"\u003e***CANNOT SHIP OUTSIDE THE UNITED STATES\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eFor 30 Gallon Tank, No citranox included.\u003c\/p\u003e\n\u003cp\u003eThis Kit Includes:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e1 Bottle of General Corrosion Inhibitor\u003c\/li\u003e\n\u003cli\u003e1 Bottle of Copper Corrosion Inhibitor\u003c\/li\u003e\n\u003cli\u003e1 Bottle of Biocide\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFull contents of each bottle is added to the Distilled water in the chiller tank.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eDirections\u003c\/h4\u003e\n\u003ch2\u003eWater Flushing Procedure\u003c\/h2\u003e\n\u003cp\u003eThe purpose of these procedures is to make sure that new water and chemicals are installed in the chiller every three months for optimal performance of the laser cooling system. In addition, every sixth month the cooling system is also flushed of all debris and unwanted chemicals.\u003c\/p\u003e\n\u003ch2\u003eEvery 3 months:\u003c\/h2\u003e\n\u003cp\u003eReplace water by using these steps:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eDrain all the water in the tank\u003c\/li\u003e\n\u003cli\u003eFill with new distilled water\u003c\/li\u003e\n\u003cli\u003eAdd the full contents of each of the three bottles \u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eto the Distilled water in the chiller tank: \u003cspan data-mce-fragment=\"1\"\u003eGeneral Corrosion\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e Inhibitor, Copper Corrosion Inhibitor, and Biocide.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eEvery 6 months:\u003c\/h2\u003e\n\u003cp\u003eReplace water by using these steps:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eDrain all the water in the tank\u003c\/li\u003e\n\u003cli\u003eFill tank with tap water\u003c\/li\u003e\n\u003cli\u003eAdd the pre-measured bottle of \u003cspan data-mce-fragment=\"1\"\u003eCitranox\u003c\/span\u003e, or 0.5 gal of Citranox per 50 gal of water.\u003c\/li\u003e\n\u003cli\u003eRun the chiller for 6 hours with high voltage on\u003c\/li\u003e\n\u003cli\u003e Flush out all the Ctiranox:\u003c\/li\u003e\n\u003col\u003e\n\u003cli\u003eDrain all the water in the tank\u003c\/li\u003e\n\u003cli\u003eFill the tank with tap water only\u003c\/li\u003e\n\u003cli\u003eRun the chiller for 10 minutes\u003c\/li\u003e\n\u003cli\u003eRepeat 4 time to be sure all the Citranox is out of the water.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cli\u003eWith the tank empty, fill the tank using the “Every 3rd month” instructions.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Mazak®","offers":[{"title":"Default Title","offer_id":42651496546382,"sku":"ChillerChemMG30","price":130.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/1270\/7918\/files\/chemkits_3b914d7f-734a-421b-9468-63268278d67f.jpg?v=1781003063"},{"product_id":"pre-measured-chiller-water-additive-kit-with-citranox-50-gallon-tank","title":"Pre-Measured Chiller Water Additive Kit with Citranox - 50 Gallon Tank","description":"\u003ch5\u003e\u003cspan style=\"color: #b63a22;\"\u003e***CANNOT SHIP OUTSIDE THE UNITED STATES\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFor 50 Gallon Tank, Pre-Measured bottle of Citranox included.\u003c\/p\u003e\n\u003cp\u003eThis Kit Includes:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e1 Bottle of General Corrosion Inhibitor\u003c\/li\u003e\n\u003cli\u003e1 Bottle of Copper Corrosion Inhibitor\u003c\/li\u003e\n\u003cli\u003e1 Bottle of Biocide\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e1 Bottle of Citranox (only enough for a 50 gallon tank)\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFull contents of each bottle is added to the Distilled water in the chiller tank.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eDirections\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch2\u003eWater Flushing Procedure\u003c\/h2\u003e\n\u003cp\u003eThe purpose of these procedures is to make sure that new water and chemicals are installed in the chiller every three months for optimal performance of the laser cooling system. In addition, every sixth month the cooling system is also flushed of all debris and unwanted chemicals.\u003c\/p\u003e\n\u003ch2\u003eEvery 3 months:\u003c\/h2\u003e\n\u003cp\u003eReplace water by using these steps:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eDrain all the water in the tank\u003c\/li\u003e\n\u003cli\u003eFill with new distilled water\u003c\/li\u003e\n\u003cli\u003eAdd the full contents of each of the three bottles \u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eto the Distilled water in the chiller tank: \u003cspan data-mce-fragment=\"1\"\u003eGeneral Corrosion\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e Inhibitor, Copper Corrosion Inhibitor, and Biocide.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eEvery 6 months:\u003c\/h2\u003e\n\u003cp\u003eReplace water by using these steps:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eDrain all the water in the tank\u003c\/li\u003e\n\u003cli\u003eFill tank with tap water\u003c\/li\u003e\n\u003cli\u003eAdd the pre-measured bottle of \u003cspan data-mce-fragment=\"1\"\u003eCitranox\u003c\/span\u003e, or 0.5 gal of Citranox per 50 gal of water.\u003c\/li\u003e\n\u003cli\u003eRun the chiller for 6 hours with high voltage on\u003c\/li\u003e\n\u003cli\u003e Flush out all the Ctiranox:\u003c\/li\u003e\n\u003col\u003e\n\u003cli\u003eDrain all the water in the tank\u003c\/li\u003e\n\u003cli\u003eFill the tank with tap water only\u003c\/li\u003e\n\u003cli\u003eRun the chiller for 10 minutes\u003c\/li\u003e\n\u003cli\u003eRepeat 4 time to be sure all the Citranox is out of the water.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cli\u003eWith the tank empty, fill the tank using the “Every 3rd month” instructions.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Mazak®","offers":[{"title":"Default Title","offer_id":42651496579150,"sku":"ChillerChemMG50-C","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/1270\/7918\/files\/withcitranox_c62e7898-bbaa-412e-aef6-f36f54e0d2b1.jpg?v=1781003063"},{"product_id":"chiller-flushing-kit","title":"Chiller Flushing Kit","description":"\u003cp\u003eThis Kit Includes:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e1 Gallon of Citranox\u003c\/li\u003e\n\u003cli\u003e1 Gallon of Isogard\u003c\/li\u003e\n\u003cli\u003e16 oz of GAX-26\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eCitranox\u003c\/h2\u003e\n\u003cp\u003eCitranox is an acidic cleaner and detergent that is biodegradable. It is used to flush the Chiller (water cooler). Use 1\/2 gallon of Citranox per 50 gallons of water.\u003c\/p\u003e\n\u003ch2\u003eIsogard\u003c\/h2\u003e\n\u003cp\u003e1 gallon of Corrosion Inhibitor. Use 1\/2 gallon of Isogard per 50 gallons of distilled water. Replace the water every 3 months or as recommended by the manufacturer.\u003c\/p\u003e\n\u003ch2\u003eGAX-26\u003c\/h2\u003e\n\u003cp\u003e16 oz bottle of an industrial microbiocide for use in recirculating water coolers. Use 5 oz per 50 gallons of distilled water. Replace the water every 3 months or as recommended by the manufacturer.\u003c\/p\u003e\n\u003ch3\u003eWater Flushing Procedure\u003c\/h3\u003e\n\u003cp\u003eThe purpose of these procedures is to make sure that new water and chemicals are installed in the chiller every three months for optimal performance of the laser cooling system. In addition, every sixth month the cooling system is also flushed of all debris and unwanted chemicals.\u003c\/p\u003e\n\u003ch2\u003eEvery 3rd month:\u003c\/h2\u003e\n\u003cp\u003eReplace water by using these steps:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eDrain all the water in the tank\u003c\/li\u003e\n\u003cli\u003eFill with new distilled water\u003c\/li\u003e\n\u003cli\u003eAdd 0.5 gal of ISOGUARD per 50 gal of distilled water used\u003c\/li\u003e\n\u003cli\u003eAdd 5 oz. of GAX-26 per 50 gal of distilled water used\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eEvery 6th month\u003c\/h2\u003e\n\u003cp\u003eReplace water by using these steps:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eDrain all the water in the tank\u003c\/li\u003e\n\u003cli\u003eFill tank with tap water and 0.5 gal of CITRONOX per 50 gal of water.\u003c\/li\u003e\n\u003cli\u003eRun the chiller for 6 hours with high voltage on\u003c\/li\u003e\n\u003cli\u003e a. Drain all the water in the tank\u003c\/li\u003e\n\u003col\u003e\n\u003col\u003e\u003c\/ol\u003e\n\u003c\/ol\u003e\n\u003c\/ol\u003e\n\u003cp\u003e                     b. Fill the tank with tap water only\u003c\/p\u003e\n\u003cp\u003e                     c. Run the chiller for 10 minutes\u003c\/p\u003e\n\u003cp\u003e                     d. Repeat steps a through c at least 3 times.\u003c\/p\u003e\n\u003cp\u003e      5. This will flush the tank and the lines of unwanted debris and chemicals.\u003c\/p\u003e\n\u003cp\u003e      6. With the tank empty, fill the tank using the “Every 3rd month” instructions.\u003c\/p\u003e\n\u003cp\u003eParts Used: Gax-26, Citranox, Isogard.\u003c\/p\u003e","brand":"Mazak®","offers":[{"title":"Default Title","offer_id":42651627683918,"sku":"ChillerKit","price":236.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/1270\/7918\/files\/Isogard-1_2aa7b722-b66b-4375-b7da-4c739181df1e.jpg?v=1781003025"},{"product_id":"citranox","title":"Citranox","description":"\u003cp\u003eCitranox is an acidic cleaner and detergent that is biodegradable. It is used to flush the Chiller (water cooler).\u003c\/p\u003e\n\u003cp\u003eUse 1\/2 gallon of Citranox per 50 gallons of water.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan style=\"color: #b63a22;\"\u003e***CANNOT SHIP OUTSIDE THE UNITED STATES\u003c\/span\u003e\u003c\/h5\u003e","brand":"Mazak®","offers":[{"title":"Default Title","offer_id":42651779366990,"sku":"Citranox","price":91.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/1270\/7918\/files\/Citranox-1_4fa0ee19-312d-4a8a-9365-4615f728cc5d.jpg?v=1781003041"},{"product_id":"isogard","title":"Isogard","description":"\u003cp\u003e1 gallon of Corrosion Inhibitor.\u003c\/p\u003e\n\u003cp\u003eUse 1\/2 gallon of Isogard per 50 gallons of distilled water.\u003c\/p\u003e\n\u003cp\u003eReplace the water every 3 months or as recommended by the manufacturer.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan style=\"color: #b63a22;\"\u003e***CANNOT SHIP OUTSIDE THE UNITED STATES\u003c\/span\u003e\u003c\/h5\u003e","brand":"Mazak®","offers":[{"title":"Default Title","offer_id":42651779924046,"sku":"Isogard","price":110.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/1270\/7918\/files\/Isogard-1.jpg?v=1781003039"},{"product_id":"gax-26","title":"GAX-26","description":"\u003cp\u003e16 oz bottle of industrial microbiocide for use in recirculating water coolers.\u003c\/p\u003e\n\u003cp\u003eUse 5 oz per 50 gallons of distilled water.\u003c\/p\u003e\n\u003cp\u003eReplace the water every 3 months or as recommended by the manufacturer.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e\u003cspan style=\"color: #b63a22;\"\u003e***CANNOT SHIP OUTSIDE THE UNITED STATES\u003c\/span\u003e\u003c\/h5\u003e","brand":"Mazak®","offers":[{"title":"Default Title","offer_id":42651779956814,"sku":"Gax-26","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/1270\/7918\/files\/Gax-1.jpg?v=1781003039"}],"url":"https:\/\/shop.mac-tech.com\/collections\/chiller-chemicals.oembed","provider":"Mac-Tech Store","version":"1.0","type":"link"}